Toshiba e-STUDIO2010AC Imaging Manual page 65

Hide thumbs Also See for e-STUDIO2010AC:
Table of Contents

Advertisement

Color
Target
mode
Manual
density
Full color
Automatic
density
• When the manual setting value of the manual density is altered while it is set in the [Basic] menu
on the control panel, the density in the steps in all the indicators including the center value is also
changed. One step in the indicator corresponds to "20" of the setting value in [05] code.
After increasing the copy density, copy and check the copy image quality.
If further image quality adjustments are still necessary, perform the next procedure.
(4) Press [Image] tab on the control panel. Press [Sharpness]. Press [Sharp] or [Soft] to adjust the
image quality.
After increasing the sharpness intensity, copy and check the copy image quality.
With the sharpness or softness intensity set to the maximum, if further image quality adjustments
are still necessary, the service technician must use the following procedure.
(5) Select [05 ADJUSTMENT MODE] and change the setting values for the codes from [7794] to [7800]
to adjust the sharpness level of the text.
• The code to use varies according to the original mode. Select the [05] code for the original mode
in which the image quality is to be changed, and start the adjustment from the setting value "128".
Original mode
[05] code
Text/Photo
05-7796
Text
05-7797
Printed Image
05-7798
Photo
05-7799
Map
05-7800
User Custom
05-7795
Red Seal Color
05-7794
• Setting "0" provides the softest image, while setting "255" provides the sharpest image.
Changing the values for these codes will change the sharpness intensity, when the [Sharpness]
indicator in the [Image] menu is set to the center. Remember that 1 step of the indicator will
© 2018 TOSHIBA TEC CORPORATION All rights reserved
Original mode
[05]code
Text/Photo
05-7713
Text
05-7714
Printed Image
05-7715
Photo
05-7716
Map
05-7717
User Custom
05-7718
Red Seal Color
05-7719
Text/Photo
05-7720
Text
05-7721
Printed Image
05-7722
Photo
05-7723
Map
05-7724
User Custom
05-7725
Red Seal Color
05-7726
Recommended value
To make the level sharper:
Set a value larger than 128.
To make the level softer: Set
a value smaller than 128.
2-11
2.Copier-specific Adjustments
Recommended
Acceptable
value
value range
To make the copy
density darker: Set
a value larger than
128.
To make the copy
density lighter: Set
a value smaller
than 128.
Acceptable value range
0 to 255
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
Default
0 to 255
128
0 to 255
128
Default
128

Hide quick links: