5.Scanning-specific Adjustments
(3) Select [05 ADJUSTMENT MODE]. Change the values for codes [7436 to 7439], [7441], [8309 to
8311] and [8370] to decrease the background density.
• The code to use varies depending on original mode. Adjust the value for [05] code corresponding
to the color mode for which you would like to improve the image quality.
Color mode Original mode [05] code
Text/Photo
Text
Full color
Photo
User Custom
Gray scale
---
Text/Photo
Text
Black
Photo
User Custom
• As for the Drop out color function, select [05 ADJUSTMENT MODE] and change the setting value
for the code [7442] to adjust the background density.
Color mode
Function
Black
Drop out color
• The setting value "25" corresponds to one step in the background adjustment on the control
panel.
• The background density will become the lowest, if "0" is set. On the other hand, it will become the
highest, if "255" is set. Changing the value will also change the background density, when the
"Background Adjustment" indicator is set to the center. Then, if the background density of the
center value is changed, each step of the indicator will be changed accordingly. (For instance, if
the center value is decreased by "5" (lighter), the value of each step of the indicator will also be
decreased by "5" (lighter)).
 Caution after the adjustment
The adjustment may possibly diminish the quality of the light-colored image. Therefore, carefully perform
the adjustment, while checking the scanned-in image.
 Remarks
When scanning the original, use the following steps to change the default indicator position in the
background adjustment option, which is displayed on the Control Panel:
(a) Press [User Functions -User-] on [Home] screen to enter the "User Functions" menu.
(b) Press [Scan].
(c) Press [Next] twice to display the menu to change the initial values for the Full color and Auto
color modes.
(d) Select the default background density in the "Background Adjustment" option.
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
Recommended value
05-8309
05-8310
05-8311
05-8370
05-7439
Set a value smaller than 128.
05-7436
05-7437
05-7438
05-7441
Recommended
[05] Code
value
Set a value smaller
05-7442
than 128.
5-4
Acceptable
value range
0 to 255
Acceptable
value range
0 to 255
© 2018 TOSHIBA TEC CORPORATION All rights reserved
Default
128
Default
128