1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
After adjusting the density, print and check the image quality.
If further image quality adjustments are still necessary, perform the next procedure.
(3) Check the life of the consumables (particularly the drum and fuser unit) and replace them, if necessary.
• When replacing any consumable, use steps (a) to (c).
(a) Enter the PM support mode. Reset the counter corresponding to the replaced consumable to "0".
For further information regarding the PM support mode, refer to the Service Manual.
(b) Select [05 ADJUSTMENT MODE], select code [2742], and then press the [START] button.
Image quality control will be performed and the image quality control value will be initialized.
(c) Perform automatic calibration in the same manner as in procedure (1).
• After replacing any consumable, remember to reset the counter corresponding to it to "0".
Otherwise, it may cause a loss in MFP performance, including degradation in the image quality
and a reduction in the life of the consumables.
 Caution after the adjustment
Nothing in particular.
 Remarks
• Enter the value mentioned in the procedures or one within the recommended value range for the
adjustment. Otherwise, it may cause a loss in MFP performance, including degradation in the image
quality and a reduction in the life of the consumables.
• If printing on another type of paper causes a problem with the image quality after the adjustment,
return the setting values (for codes 05-2934 to 2937) to the default (setting value: 5) and then perform
the adjustment again.
• When replacing any consumable, refer to the relevant information in the Service Manual.
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
© 2018 TOSHIBA TEC CORPORATION All rights reserved
1-6