Sia Mode Messages; Acron Super Fast (Message Type 9) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2

SIA Mode Messages

Use the SIA mode for central station monitoring.
3.2.1

Acron Super Fast (Message Type 9)

Acron Super
SIA Mode Description
Fast Example
<LF><CRC><9><sequence#><receiver#><line#>[#aaaa|CCCCCCCC]<CR>
Table 41: Acron Super Fast (Message Type 9) Byte Description
Title
L
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account#
Figure 7: Message sent to printer
mm/ddshh:mmsLxxsACNsACCTsaaaa
+++sACCTsaaaasCCCCsCCCC
For lines that are grouped, Gxx appears instead of Lxx.
Table 42: Acron Super Fast (Message Type 9) Printer Output
Characters
Description
ACN
Acron Super Fast format.
Lxx
Line number.
Gxx
Grouped line numbers.
44
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical redundancy check number.
9
The message sequence number. The valid sequence number range is
0001 to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
The communicator's account number has four digits.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100ipv6Conettix d6100i

Table of Contents