Modem IIe Format
DD/MM HH:MM:SS NNN > (DDDD) AA EE ZZZ
Modem IIe messages are reported as AA EE ZZZ where AA is the area code, EE is the event code from
Table , and ZZZ is the zone or user code. For example: 01 EF 009 = area 1, alarm zone 9.
Table 125:
Supported Event Codes
Code
Meaning
FE
Listen in.
FD
Fail to call RAM.
FC
Access granted.
FB
Duress user ZZZ.
FA
User ZZZ alarm 7.
F9
User ZZZ alarm 9.
F8
Point ZZZ bypass.
F7
Point ZZZ forced bypass.
F6
Status = alarm ZZZ.
F5
Status = trouble ZZZ.
F4
Fire alarm ZZZ.
F3
Fire trouble ZZZ.
F2
Missing fire ZZZ.
F1
Fire restore ZZZ.
F0
Fire trouble restore ZZZ.
EF
Alarm ZZZ.
EE
Trouble ZZZ.
ED
Restore ZZZ.
EC
Missing alarm ZZZ.
EB
Missing trouble ZZZ.
EA
Point ZZZ open.
E9
Point ZZZ close.
E8
Extra point ZZZ.
E7
Point bus trouble.
E6
All points tested.
E5
Restoral from alarm.
E4
Fire cancel.
E3
User code added.
E2
Service start.
E1
Service end.
E0
Sensor ZZZ reset.
DF
Relay ZZZ set.
DE
Relay ZZZ reset.
DD
Panel was forced armed.
DC
Create status report.
DB
Fire walk start by user ZZZ.
DA
Fire walk end.
D9
Walk test start by user ZZZ.
D8
Walk test end.
178
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Code
Meaning
D4
Walk test point.
D3
Extend close time by user ZZZ.
D2
Cancel by user ZZZ.
D1
Status = open.
D0
Open by user ZZZ.
CF
Force close by user ZZZ.
CE
Status = closed.
CD
Close by user ZZZ.
CC
Test report.
CB
Log at threshold.
CA
Log overflow.
C9
Parameter change.
C8
User code tamper by user ZZZ.
C7
User code for user ZZZ added or changed.
C6
Sked ZZZ execute.
C5
Sked ZZZ changed.
C4
Date changed by user ZZZ.
C3
Time changed by user ZZZ.
C2
User level set by user ZZZ.
C1
Valid programmer access by SDI device ZZZ.
Invalid programmer access by SDI device
C0
ZZZ.
BF
Valid RAM access on phone ZZZ.
BE
Invalid RAM access on phone ZZZ.
BD
Comm fail phone ZZZ.
BC
Comm restore phone ZZZ.
BB
Phone line ZZZ fail.
BA
Phone line ZZZ restore.
B9
SDI device ZZZ trouble.
B8
SDI device ZZZ restore.
B7
Panel AC fail.
B6
Panel AC restore.
B5
Panel battery missing.
B4
Panel battery low.
B3
Panel battery restore.
B2
Panel watchdog activated.
B1
Supervision (non-fire) ZZZ.
B0
Remote reset.
AF
ROM checksum failure.
AE
Memory failure.