Adt Sia (Message Type S) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.7

ADT SIA (Message Type S)

ADT SIA
D6500 Byte Description
Example
1
2
h
S
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
y
t
Table 9:
ADT SIA (Message Type S) Byte Description
#
Title
1
Header Character
(h)
2
Message Type
3-4
Receiver Number
5
Line/Group
Number
6
space
7
#
8-11
Account Number
12
|
13-32
Date and Time
33
E
34-35
Event Code
36-39
Zone
40
/
41
***
42
Trailer Character
14
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3
4
5
6
7
8
r
r
l
[
#
a
I
h
h
:
m
m
Description
Optional. Check with the computer automation software for
compatibility.
S
Receiver gateway number from 01 to 99.
Line number in the receiver gateway that sent the message.
One space.
#
Up to sixteen digits in the account number.
Separator. Indicates more data positions after account number.
Date and time.
SIA block code.
SIA event code (refer to Appendix G: ADT SIA Report Codes).
Zone number.
Separator.
Next block of data.
Typically, this is HEX 14.