Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.3
Ademco 4-2 Express (Message Type c)
4-2 Express
D6500 Byte Description
Example
1
2
h
c
Table 5:
Message Type c (Ademco 4-2 Express) Byte Description
#
Title
1
Header Character
(h)
2
Message Type
3-4
Receiver Number
5
Line/Group
Number
6-11
Spaces
12-15
Account Number
16
Space
17
E
18-19
Spaces
20-21
XY
22
Trailer Character
10
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
3
4
5
6
7
8
r
r
l
s
s
s
Description
Optional. Check with the computer automation software for
compatibility.
c
Receiver gateway number from 01 to 99.
Line number in the receiver gateway that sent the message.
Six spaces.
Account number, four digits.
One space.
Event Code, "A" as the default.
Two spaces.
Event code and zone number.
Typically, this is HEX 14.
9
10 11 12 13 14 15 16 17 18 19 20 21 22
s
s
s
a
a
a
a
s
E
s
s
X
Y
t