Ademco Contact-Id (Message Type A) - Bosch Conettix D6600 Manual

Computer interface of receiver/gateway
Table of Contents

Advertisement

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.2

Ademco Contact-ID (Message Type a)

Contact-ID
SIA Mode Description
Example
<LF><CRC><a><sequence#><receiver#><line#>[#aaaa|18QXYZGGCCC]<CR>
Table 43: Ademco Contact-ID (Message Type a) Byte Description
Title
LF
CRC
Message Type
sequence#
receiver#
line#
(Line/Group #)
account#
18
Q
XYZ
GG
CCC
Figure 8: Message sent to printer
mm/ddshh:mmsLxxsCIDsACCTsaaaa
+++sACCTsaaaasNNNsEVENT=XYZsG=GGsC=CCC
For lines that are grouped, Gxx appears instead of Lxx.
Table 44: Ademco Contact-ID (Message Type a) Printer Output
Characters
Description
CID
Contact-ID format.
Gxx
Grouped Line numbers.
Lxx
Line number.
NNN
If Q = 1, print E/O for new event or opening If Q = 3, print R/C for restore or closing
If Q = 6, print "OLD" for old messages and events.
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05
Description
Standard line feed character.
Cyclical redundancy check number.
a
The message sequence number. The valid sequence number range is
0001 to 9999.
The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.
The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.
The communicator's account number has four digits.
Ademco Contact-ID format number.
Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 =
Previous event.
Class code and event code (refer to Appendix A: Contact ID Event Code
Classifications).
Group number.
Zone codes or User ID.
45