1 Alarms
1.5.1 Alarm description
No.
Name
73
SG correction factor 15
74
SG correction factor 16
75
Velocity limit n
x
76
Stop reaction with SG1
77
Stop reaction with SG2
78
Stop reaction with SG3
79
Stop reaction with SG4
80
SI modulo value for SN
81
Speed tolerance for SBR
1000 Control timer expired
1001 Control timer initialization error The SGE modification timer did not start the control
1002 User enable timer expired
1003 Reference tolerance violated
1004 Plausibility violation of user
enable
1005 Pulses already deleted on test
stop selection
1006 Error on SGA forced dynamic
response
1007 Breakdown of the communi-
cation between PLC and drive
1008 Erroneous data transfer bet-
ween PLC and drive
Note:
If the value 12 is stored in this value, the cross–comparison has detected a difference in the MD for lower limit SE1 in the NCK
and drive monitoring channel.
1–78
Explanation
MD 1301 bit 5 is not 0
MD 1301 bit 5 is not 0
MD 4292* and MD 1346 not equal
MD 4508*.4, 4508*.5 and MD 1361 not equal
MD 4508*.4, 4508*.5 and MD 1361 not equal
MD 4508*.4, 4508*.5 and MD 1361 not equal
MD 4508*.4, 4508*.5 and MD 1361 not equal
MD 1367 is not 0
MD 4296* and MD 1348 not equal
The SGE modification timer did not expire within
the time of the control timer (i.e. too many switching
operations in SGEs).
timer.
Different status of user enable from drive and NCK
The comparison of stored standstill position and
current position has a greater deviation than speci-
fied in MD 4252*: actual value tolerance (referenc-
ing) or MD 1344
The user enable has been specified for an axis
which is
already referenced
not yet referenced
The "pulses are deleted" signal is already active on
test stop selection
An error was detected on the cyclic check of the
SGAs.
If the drive releases a breakdown in communica-
tion, either the PLC or the NC has broken down.
The data transfer of the SGEs/SGAs between PLC
and drive is guaranteed by a checksum. In the
event of an error, the calculated checksum does
not coincide with the transferred checksum. If the
stop is released by the drive, either the PLC or the
NC has broken down.
Siemens AG 2001 All rights reserved 6FC5198–jAB40
Cause, Remedy
Enter MDs equal
Enter MDs equal
Enter MDs equal
Enter MDs equal
Enter MDs equal
Enter MDs equal
Enter MDs equal
e.g. contact problems (loose con-
tact)
Test stop selection on pulse en-
able error during wiring of the
"pulses are deleted" SGE
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
07/97