Error Display On Cpu; Error List Of The Plc; Error Display On The Mmc Cpu - Siemens Sinumerik 840C Diagnostics Manual

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

3

Error Display on CPU

Errors that prevent normal operation of the PLC or the IF PLC, are displayed by a
flashing LED on the front panel of the module in question.

Error list of the PLC

LEDs for PLC
Steady light (green only)
Steady light (red only)
Steady light (red and green)
Light flashing (red)
once
3 times
4 times
5 times
6 times
7 times
9 times
10 times
11 times
12 times
13 times
14 times
15 times
16 times
17 times
LED for IF PLC
Steady light (green only)
Steady light (red only)
Light flashing (red)
12 times
13 times
LED off
Note
If the PLC 135 WB2 is used, the LEDs for the PLC and IF PLC are situated on the
PLC 135 WB2 or interface PLC module. If the PLC 135 WD is used, all the LEDs
are situated on the front panel of this module.
Error display on
the MMC CPU
Figure
0
1
2
3
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
Meaning (SINUMERIK 840C)
PLC cyclic mode
PLC in STOP state
OVERALL RESET necessary (initial power-up or data loss)
Error on cross-check sum over system program submodule
Timer 0 error (process-internal timer) or watchdog error
SW3: Module is a PLC 135 WB (can no longer be used)
Access to link RAM not possible
Error with test access to link RAM
SW1 and SW2: Error in system initialization program (synchronization
pattern)
SW3: No communication with MMC
SW3: Error when booting
1 ACOP error (group error)
IF PLC cannot be addressed from PLC
RAM of the IF PLC defective (program memory or CPU RAM)
Dual port RAM of the IF PLC defective
ADS link to the NC defective
ADS link to the IF PLC defective
ADS link (reserved); SW3 and higher: ADS link to MMC defective
ADS link (reserved)
IF PLC in cyclic operation (no error), MPC transmission running
IF PLC in the STOP state
RAM of the IF PLC defective (CPU-RAM)
Dual port RAM of the IF PLC defective
No MPC transmission, processor running
Driver not loaded
Driver loaded but ADS power-up not yet performed
Jump ADS interface power-up
ADS interface power-up, MMC waits for '0' from NC
3 Error Display on CPU
Meaning
Meaning
3–1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents