04/96
104005
Caution File has lines which are too long
Scan
When reading in file
Effect
Line wrapround with LF
Explanation
Line length > 128 characters (as from SW 4: > 256 characters)
Remedy
–
Note
Applies up to SW 4.5
104005
File or harddisk failure
Scan
in ASCII editor
Effect
Operation aborted.
Explanation
An error has occurred in the editor during a write/read operation on the hard disk.
Remedy
Perform chkdisk;
replace MMC
Note
Aplies as from SW 5
104006
The hard disk is full
Scan
When expanding the current file in ASCII editor
Effect
Operation is aborted
Explanation
The ASCII editor cannot generate any further internal auxiliary files
Remedy
Reduce number of files on the hard disk.
Note
Applies up to SW 4.4
104006
File cannot be processed further
Scan
ASCII editor
Effect
Explanation
Possible causes are
1. File is 8 MB
2. File 8 MB was processed further
3. Hard disk is full
4. Hard disk error
S
Remedy
for 1, 3, 4: exit file without saving
S
for 2:
Note
Applies as from SW 4.4
104007
Line wrapround due to excessively long lines
Scan
When reading in file
Effect
–
Explanation
Line length > 128 characters (as from SW 4: > 256 characters)
Remedy
–
104008
Save not possible at present time
Scan
When saving file
Effect
File is not saved
Explanation
File is still open somewhere else (e.g. execution from harddisk)
Remedy
Wait until execution has ended
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
changes made up to this message can be saved.
1 Alarms
1.5.1 Alarm description
OK softkey
OK softkey
OK softkey
OK oftkey
OK softkey
OK softkey
1–101