Error Messages When Using The Plm And C High-Level Languages; Timeouts; Error Messages Of Distributed I/Os; Cycle Time Monitoring - Siemens Sinumerik 840C Diagnostics Manual

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

04/96
98
Timeout with transfer in/out (see errors B0 and B1)
99
Timeout cannot be interpreted with active interpreter *)
9A
Timeout with processing a function macro *)
9B
Timeout with processing high-level language blocks *)
9C
Timeout with access to pabe
commands LB CB, LB CW, LB CD, TB CB, TB CW, TB CD
W A0
Transfer error to an expansion unit
W A1
Overtemperature in an expansion unit or bouncing enable input with SIMATIC I/O devices
W A2
Interface DMP outputs a command output disable during operation
W A3
Transmission link to EU 185U (SIMATIC EU) has failed
W AF
Message "OUTDS" from power supply unit
W B0
Input module failed or changed and STOP set for PLC for this module via MD *)
W B1
Output module failed or changed and STOP set for PLC for this module via MD *)
C0
Cycle time exceeded
C1
Cycle time exceeded; FB12 called more than twice per cycle
Error messages when
using the PLM and C
high-level languages
D0
Unknown type identifier in parameter declaration of the FB called
D1
Illegal type identifier block
D2
Unknown code in the parameter block of the FB called: input parameter
D3
Unknown code in the parameter block of the FB called: output parameter
D4
Unknown pseudo parameter in STACK
D5
Block not available
D6
HLL block not in line with paragraph
D7
Block called is not a HLL block
D8
DB to be opened in HLL: wrong pseudo parameter
D9
DB to be opened not available
DA
DB to be opened not in line with paragraph
*) Additional information is given on this error in additional fields (see Section 2.2)
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
2.1 Error numbers (ACCU 3 high byte, DB 1 DW 160)

Timeouts

Error messages of distributed I/Os

Cycle time monitoring

HLL call in the interpreter
HLL_HLL function
HLL_ADB function
2 Diagnostics on the PLC
2–5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents