(6)
Rotate carriage-2 [1] in the direction shown
in the figure, while trying not to touch the
mirror. Then remove carriage-2 [1].
Notes:
Replace mirror-2 and -3 together with
carriage-2 [1]. Do not remove mirror-2 and -
3.
[B] Installing the carriage wire
(1)
As shown on the right, replace the carriage
wire and install a new wire.
[1] Wire pulley
[2] Carriage wire
[3] Carriage-2
[4] Idler pulley
[5] Hook
[6] Tension spring
[7] Front side
[8] Rear side
Notes:
It is not necessary to adjust the carriage wire
tension since a certain tension is applied to
the carriage wires through the tension
springs. Make sure the tension applied to the
wire is normal.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
DISASSEMBLY AND REPLACEMENT
Fig. 4-159
[7]
[1]
[6]
Fig. 4-160
[8]
[3]
[4]
[5]
Fig. 4-161
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 56
[3]
[2]
[4]
[5]
[2]
[1]
[6]