Scanner <E-Studio207L/257/307/357/457/507> - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

4.6
SCANNER <e-STUDIO207L/257/307/357/457/507>
Notes:
Since the scanner section is assembled with high precision, be sure not to perform any
disassembling other than that instructed in the Service Manual.
4.6.1
Original glass
(1)
Take off the right upper cover.
 P. 4-11 "4.2.5 Right upper cover"
(2)
Remove 2 screws and take off the original
glass [1].
Notes:
Make sure that the RADF original glass
[2] is securely inserted into the groove of
the fixing part of the original glass [1].
Securely insert the 2 pins of the original
glass [1] into the holes in the frame.
(3)
Take off the RADF original glass.
4.6.2
Lens cover
(1)
Take off the original glass.
 P. 4-45 "4.6.1 Original glass"
(2)
Remove 2 screws. Lift the lens cover [1] and
then take off the lens cover toward the left
side.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
[2]
Fig. 4-130
[2]
Fig. 4-131
Fig. 4-132
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 45
[1]
DISASSEMBLY AND REPLACEMENT
4