Interference Prevention Setting - Panasonic GP-X Series User Manual

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

4.7 Interference Prevention Setting

Connect the interference prevention output (terminal No. 7) at the external
terminal and the interference prevention input (terminal No. 16) to switch the
detection action alternately to prevent mutual interference from occurring.
Because the detection action switching signal is automatically generated,
there is no need to supply pulse signals for switching the action.
Designate one controller as a master, while designating the others as slaves
to validate interference prevention.
Notice
POINT
If the interference prevention function is used, continuity in sampling is lost
and measurement is made intermittently.
Connection method
Example of connection of three units
1) Connect interference prevention cables and turn the power on.
Interference
prevention output
Interference
prevention input
2) Designate controller 1 as a master.
<Setting 1 mode>
90
Ramco Innovations www.ramcoi.com
To mount sensor heads close together, perform three-point calibra
point calibration cannot be set.
If "master" or "slave" is designated without connecting the external
terminal, the correct function will not be obtained.
Controller 1
INT.Pout
7
INT.Pin
16
Master
Press
to select "Int_P".

Interference prevention setting

mode
Controller 2
Controller 3
7
7
16
16
Slave
Slave
Press
to select "master".
Set
(Master)
Phone 800-280-6933 nsales@ramcoi.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp-x3sGp-x5sGp-x8sGp-x10mGp-x12mlGp-x22kl

Table of Contents