Panasonic GP-X Series User Manual page 45

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

Displayed value
Timing input
Reset input
Internal sampling
*In the external trigger mode, the trigger delay and sampling time settings are ignored.
Ramco Innovations www.ramcoi.com
External Trigger Mode
Example of peak hold
0
ON
OFF
ON
OFF
Sampling
Sampling period 2
period 1
Start of holding mode
Output of result of
sampling period 2
Output of result
of sampling
period 1
Sampling period 3
Phone 800-280-6933 nsales@ramcoi.com
Measured value
Measurement
Displayed value
Output value
Output of result of
sampling period 4
Sampling
Sampling period 5
period 4
Time
39