4.3.3 Output Delay

Indication in lower line
The timing for switching the judgment output from ON to OFF retreats with
the timer setting.
The timing chart is shown below.
[Timer type and change in GO output (in the case of "to" timer setting)]
Regular output
(without timer)
Off-delay timer
POINT
74
Ramco Innovations www.ramcoi.com
Delay
No delay
100ms
200ms
400ms
800ms
1,000ms
Hold
ON
OFF
ON
OFF
・The delay becomes longer with the interference prevention setting.
Actually operate to check. For details, refer to Section "4.7 Interference
prevention Setting" on page 90.
・If the number of connected units is as large as eight, the delay is 12.8
times (19.2 times with GP-X22KL) that of a single unit.
Description of action
No delay
100ms off-delay
200ms off-delay
400ms off-delay
800ms off-delay
1,000ms off-delay
Judgment output is held until the reset
signal is issued.
t