6.2 Command Lists
Basic control command
Item
Loading
measured
value
Loading
judgment
output
Hold mode
114
Ramco Innovations www.ramcoi.com
Controller
Command
Instruction character
address
string (m)
Loading
Writing
(n) 1)
0:
Displayed
value
RMD
0
1:
Detected
distance
value
ROT
0
0
RHM
0
0
m=0 to 5
0:
Normal mode
1:
Peak hold
2:
Bottom hold
WHM
0
3:
Peak-to-peak
hold
4:
Sample hold
5:
Average hold
Outline
The measured value is loaded from the
controller of the designated address.
The response to
%
E
E # R M D n m
is:
%
E
E $ R M D n
+ & &
C R
Before a trigger is detected in the hold
mode,
.
is sent back.
The judgment data is loaded from the
controller of the designated address.
The response to
%
E
E # R O T n m
is:
%
E
E $ R O T n x
x: The 4 bit judgment data is indicated
with "0" to "F."
bit 0: Lo, bit 1: Go, bit 2: Hi, bit 4: Alarm,
When x =
1 (0001b), Hi judgment output
is indicated because bit 0 is
ON.
When x =
2
(0010b),
output is indicated because bit
1 is ON.
When x =
4 (0100b), Lo judgment output
is indicated because bit 2 is
ON.
When x =
C (1100b), Lo judgment output
is indicated with an alarm
output because bit 3 and bit 2
are ON.
The hold mode setting is loaded from the
controller of the designated address.
The response to
%
E
E # R H M n 0
is:
%
E
E $ R H M n m
<Response value m>
m = 0: Normal mode
m = 1: Peak hold
m = 2: Bottom hold
m = 3: Peak-to-peak hold
m = 4: Sample hold
m = 5: Average hold
Start the hold mode on the controller of
the designated address.
The response to
%
E
E # W H M n m
is:
%
E
E $ W H M n
C R
Phone 800-280-6933 nsales@ramcoi.com
Setting
example
C R
Example 1
&
. & & & &
C R
C R
Example 2
Go
judgment
C R
C R
Example 3
C R