Final coupling, continued
Removing the cham-
ber transport cover
03- 2017
Installation
Chamber - Column Coupling
The table below shows the steps for removing the chamber transport cover:
Step
Action
6
Fit the trolley stop (34) and fix
in place using the bolts (40)
recovered from the transport
cover, hand tightening them.
7
Prepare the fitting tool (35)
by screwing the coupling pin
(24) onto its end, hand tight-
ening.
GE Information
Illustration
x 2
40
H M16- 55
35
24
Continued on next page.
L31- 7143EN/02
9/16
34