WARNING
Incorrect battery cable routing could
damage the machine and cables causing
sparks. Sparks can cause the battery
gasses to explode, resulting in personal
injury.
• Always disconnect the negative
(black) battery cable before
disconnecting the positive (red)
cable.
• Always connect the positive (red)
battery cable before connecting the
negative (black) cable.
3. Coat both battery connections with Grafo 112X
(skin-over) grease (Toro Part No. 505-47),
petroleum jelly, or light grease to prevent
corrosion.
4. Slide the rubber boot over the positive terminal.
5. Close the battery cover.
Locating the Fuses
The traction-unit fuses are located under the
power-center cover
79).
Remove the 2 screws securing the power-center
cover to the frame and remove the cover
1. Power-center cover
1. Fuses
59
(Figure
77,
Figure
78, and
(Figure
Figure 77
2. Screws
Figure 78
Figure 79
Figure
77).
g020440
g020439
decal121-1599