Others
Function
"CC-Link IE
Parameter
TSN
setting of a
Configuration"
device station
window
Detection of
connected/
disconnected
devices
Parameter
processing of a
device station
Command
execution to
device stations
Reserved station setting
Error invalid station setting
Device station parameter
automatic setting
Station number setting using a
program
Data collection using CC-Link IE
TSN Communication Software
Co-recording
Firmware update
Description
Sets parameters of device stations (the number of points
and assignment of link devices) in the master station.
Detects connected device stations and the stations are
displayed on the "CC-Link IE TSN Configuration" window.
Reads and saves the parameters from the device station,
and writes the saved parameters to the device station.
Commands to a device station (Error clear request, Error
history clear request) are executed.
Reserved station is a device station that is set in the
parameters and included as a station in the network when
its number is counted. This station reserved for network
extension in the future, and thus the station is not actually
connected, and is not detected as a faulty station despite
being not connected.
An error invalid station is a device station that is set to be
not detected as a faulty station by the master station.
Saves parameters of the device station to the master
station, and sets the parameters automatically when the
device station is connected or returned to the network.
Sets a station number and IP address using a program to
the own station with no station number and IP address
setting. This function allows project data items of stations
with the same program and network parameters (excluding
the station numbers and IP addresses) to be the same,
leading to reduced development work hours. (
MELSEC iQ-R Programming Manual (Module Dedicated
Instructions))
Receives cyclic data on CC-Link IE TSN using CC-Link IE
TSN Communication Software.
 CC-Link IE TSN Communication Software for
Windows User's Manual
The master station or the RJ71GN11 of the local station
relays a co-recording trigger among the recording devices
on the base unit of the own station and those of other
stations.
 MELSEC iQ-R System Recorder Co-recording
Function Reference Manual
Enables users to change the firmware of modules by
obtaining firmware update files from the users' local
Mitsubishi representatives. ( MELSEC iQ-R Module
Configuration Manual)
RJ71GN11-T2
RJ71GN11-SX
Master
Local
Master
station
station
station
3 FUNCTION LIST
Local
station
3