FUNCTION LIST
The following table lists the functions of CC-Link IE TSN. For details on these functions, refer to the following.
 MELSEC iQ-R CC-Link IE TSN User's Manual (Application)
The , , and  symbols in the table have the following meanings.
: Available, : Partially available, : Not available
Cyclic transmission
This function allows periodic data communications among stations on the network using link devices.
Function
Communications using RX, RY,
RWr, and RWw
Communications using LB and
LW
Link points extended
Link refresh
Direct access to link devices
Cyclic data assurance
Communication cycle
coexistence
Interlink transmission
I/O
Output mode
maintenance
upon CPU error
settings
Output hold/clear
setting during
CPU STOP
Data link faulty
station setting
Remote device test
CANopen communications
3 FUNCTION LIST
24
Description
This allows data to be exchanged in units of bits and in
units of words between the master station and device
station.
Communicates data in units of bits and words between the
master station and local stations.
Extend the maximum number of link points per network.
LB: 32K points  128K points, LW: 16K points  512K
points
Automatically transfers data between the link devices of
the RJ71GN11 and the devices of the CPU module.
The corresponding data is directly read or written from/to
link devices of the RJ71GN11 using the program.
Assures the cyclic data integrity in units of 32 bits or
station-based units.
When device stations with different communication cycles
are included in the network, multiple communication cycles
according to each device station are used for
communications.
Transfers data in the link devices of the master station to
another network module on a relay station.
Sets whether to hold or clear output when a stop error
occurs in the CPU module. Set it on the sending side.
Sets whether to hold or clear output when the status of the
CPU module changes from RUN to STOP. Set it on the
sending side.
Sets whether to clear or hold input from a disconnected
station. Set it on the receiving side.
Arbitrarily turns on or off the output of the remote station
when the CPU module is in STOP state.
Controls a servo amplifier that supports the CANopen
profile.
RJ71GN11-T2
RJ71GN11-SX
Master
Local
Master
station
station
station
Local
station

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rj71gn11-t2Rj71gn11-sx

Table of Contents