1. FUNCTIONS AND CONFIGURATION

1.4.2 MR-J4-_A_-RJ

Wirings other than in diagram are common with MR-J4-_A_-RJ. Refer to "MR-J4-_A_(-RJ) Servo Amplifier
Instruction Manual".
MR Configurator2
Analog monitor
Personal computer, etc.
Not used
(Remove the short-circuit
connector.)
Junction terminal
block
POINT
Remove the short-circuit connector on CN8.
MR-J4-_A_-RJ MR-D30
Personal
computer
CN5
CN6
CN3
CN8
CN1
U
V
W
CN2
CN10A/CN10B
24 V DC power
supply for IO
Safety signal
1 - 9
Safety programmable
controller
Emergency stop
switch
Light curtain