7 7 . . 5 5 . . 1 1 0 0 C C o o n n n n e e c c t t T T h h e e C C o o o o l l i i n n g g M M e e d d i i a a
Connect cooling media supply to the system supply panel. 2 pcs of ½" barb fitting are fitted on ½" female
connectors close to the shut off valves.
1. Connect the feed hose/pipe to the lower port and
the return hose/pipe to the upper port.
2. Secure hoses with hose clamps.
3. Open the Shut off valves when the cooling media
hose/pipe is connected at both ends.
4. Bleed/drain air in the external system according to
its instructions.
7 7 . . 6 6 M M a a c c h h i i n n e e S S t t a a r r t t u u p p
7 7 . . 6 6 . . 1 1 P P o o w w e e r r U U p p T T h h e e M M a a c c h h i i n n e e
1. Open the Control Cabinet (left hand) side panel to
verify that all circuit breakers are switched on.
2. Turn the main power switch to O O N N position (located
at the rear of the machine).
01
IM-710429
en-GB
1. Cooling media outlet
2. Cooling media inlet
69