Download Print this page

GE ArcamEBM Spectra H Installation Manual page 21

Hide thumbs Also See for ArcamEBM Spectra H:

Advertisement

5 5 . . 4 4 S S a a f f e e t t y y E E q q u u i i p p m m e e n n t t
5 5 . . 4 4 . . 1 1 I I n n t t e e r r l l o o c c k k s s
5 5 . . 4 4 . . 2 2 L L i i g g h h t t C C u u r r t t a a i i n n
C C a a u u t t i i o o n n
Do not place your hands under the heat shield when the light curtain is activated — the heat
shield will fall down to the build table leading to possible injury. Always take out the heat shield
before performing maintenance etc. under it to eliminate the risk of injury.
01
IM-710429
en-GB
Certain machine doors and hatches are supervised by interlocked
safety switches and will shut off various machine systems when the
doors or hatches are opened.
I I n n t t e e r r l l o o c c k k e e d d s s y y s s t t e e m m s s : :
• Rake movement
• Z-actuator movement
• High Voltage Unit
C C o o m m p p r r e e s s s s e e d d a a i i r r s s u u p p p p l l y y : :
• Build table bayonet
• Door closing actuator
• Camera shutters
• Build tank actuator
The moving parts (rake and build table ) in the vacuum chamber are
guarded by a light curtain that shuts off the actuators if interrupted
when the chamber door is open
17

Advertisement

loading