Powering Off The Smart Pcs - Huawei LUNA2000-100KTL-M1 User Manual

Smart power control system
Hide thumbs Also See for LUNA2000-100KTL-M1:
Table of Contents

Advertisement

LUNA2000-100KTL-M1 Smart Power Control System
User Manual
After cleaning is complete, reinstall the air inlet baffle. Tighten the screws to a
torque of 1.2 N·m.
Removing the Air Outlet Protective Cover
Figure 7-2 Removing the protective cover
After cleaning is complete, reinstall the air outlet protective cover. Tighten the
screws to a torque of 1.2 N·m.

7.2 Powering Off the Smart PCS

Context
Perform the following procedures when powering off the Smart PCS for
maintenance or replacement to prevent personal injury and equipment damage.
● If the DC switch between the Smart PCS and the DC LV Panel busbar is
● If the AC switch between the Smart PCS and the grid is automatically turned
● Before power-off for maintenance, do not touch the energized components of
Procedure
Step 1 Wear proper personal protective equipment (PPE).
Issue 02 (2023-01-10)
NO TICE
NO TICE
CA UTION
automatically turned off, do not turn on the switch before the fault is rectified.
off, do not turn on the switch before the fault is rectified.
the Smart PCS, as this may result in electric shocks or arcs.
Copyright © Huawei Technologies Co., Ltd.
7 Device Maintenance
74

Hide quick links: