Canon DP-V1830 Operation Manual page 51

Video display
Hide thumbs Also See for DP-V1830:
Table of Contents

Advertisement

Sub Menu
Test Pattern
Signal Monitoring
Control
Error Hold
No Signal/Unsupported
Signal
2SI LinkOrder
SDI CRC Error
8K 2SI Format
Export
Error Log
Sets the test pattern built into the main unit.
White (1023)
White (940)
• If the power is turned off once and then back on, the test pattern will not be
Gray
displayed.
Black (64)
• The test pattern will be erased in the following cases:
Black (0)
- When a channel is changed using the CH button, F button assigned for
Ramp
Color Bars
- When changing [Input Configuration] or [Select Input Signal] under [Channel
Color Bars (PQ Full)
Color Bars (PQ Limited)
- When [Reset All Settings] is executed
Color Bars (HLG)
PLUGE
PLUGE (PQ/HLG)
Off
Monitors the input signal status.
• [Signal Monitoring] cannot be used in the following cases:
- When [Single Input Dual View] is displayed
- When an enlarged image is displayed
- During display of the test pattern
- During execution of [Playback File] under [Screen Capture]
• When an error is displayed, [In Monitor Display] will not be shown.
• The position the error is displayed can be adjusted with [In Monitor Display] [Position].
On, Off
Sets whether [Signal Monitoring] is used or not.
On (No time out)
Sets the length of time for displaying errors, when they are detected.
On (5 sec.)
Off
[On (No time out)]: Errors continue to be displayed. To hide the displayed
[On (5 sec.)]: The displayed error will disappear 5 seconds after the initial
[Off]: Only displays errors during the period when they are detected. The
On, Off
Displays an error when there is [No Signal] or [Unsupported Signal].
On, Off
Displays an error when the cables inserted into the input terminals are in
the wrong order when using signals input via [2 Sample Interleave].
On, Off
Displays an error when an incorrect SDI signal is detected (CRC error).
On, Off
Monitors the input signal status for the four terminals using the SDI signal
when [Channel Settings] [Select Input Signal] is set to [Automatic].
Exports the error history to USB memory. The file name is "signal_error_xxx.txt (xxx is a number)".
Displays error history.
Setting Options (Bold: factory default)
Channel UP/Channel DOWN, or [Select Channel] under [Channel Settings]
Settings]
error, press the RESET button when closing the OSD menu.
detection.
displayed error message will disappear once the error ends.
OSD Menu
51