KF 18xx/19xx
Figure 030-73: Three-Pronged Connector and VCC Control
4.40
Compressor Coil Check
1. Disconnect the appliance from the power supply.
2. Remove the VCC control; see Section 030-4.39.
3. Once the VCC control is removed, the compressor and control can be
checked. Disconnecting the 3-pronged connector (Figure 030-73, Item 1)
exposes the 3 coils. See Figure 030-74.
Figure 030-74: Three Coils on Compressor
4. Check the resistance between any two coils. All readings should be the
same (approximately 16Ω, +/-0.5Ω).
5. Check the resistance between each coil and ground to verify that no
Warning!
The VCC compressor can only be
operated via the electronic inverter.
Direct activation with supply voltage
will destroy the compressor winding.
69