Table 030-17: Fault Codes - Miele KF 18 Vi Series Technical Information

Hide thumbs Also See for KF 18 Vi Series:
Table of Contents

Advertisement

Technical Information
Code
F121
F122
F123
(refrigerator),
F124 (freezer)
F127
F141*
F142*
F143*
F144*
F145*
F146*
3
F147

Table 030-17: Fault Codes

1
The resistance value of the NTC corresponds to a temperature below -66°F (-55°C) or
above 140°F (60°C).
2
Do not replace the icemaker without first checking for the following faults:
1. Voltage fluctuations. If the fault code remains after switching the appliance off and
on, proceed to Step 2.
2. Faulty water inlet. (Check the water inlet.)
3. Water pressure too low. (Check the water pressure.)
4. Ice cube dispenser (output flap) is blocked. (Check the output flap.)
5. Faulty ice crusher. (Check the ice crusher.)
Only replace the icemaker after the above 5 possible causes have been ruled out.
3
In the compressor area, a temperature above 135°F (57°C) was detected 3 times, for
at least 5 minutes each time. The temperature readings occurred over a span of 127
minutes. During the 127 minutes the compressor is shut off so that the compressor
area can cool down. When this fault occurs, all components are shut off to avoid
damaging them from the too-high temperatures.
Displayed as
Cause
Faulty icemaker
F 01 21
Ambient-air NTC faulty.
F 01 22
Faulty electrical component.
F 01 23 or
F 01 24
Faulty cooling circuit.
Connection plug inserted
incorrectly.
F 01 27
Faulty control or power
electronic.
Refrigerator door open for 15
F 01 41
minutes.
Refrigerator door open for 30
F 01 42
minutes.
Refrigerator door open for 45
F 01 43
minutes.
Freezer door open for 15
F 01 44
minutes.
Freezer door open for 30
F 01 45
minutes.
Freezer door open for 45
F 01 46
minutes.
Insufficient ventilation to the
refrigerator. The air grille in
the toekick area is blocked.
Faulty condenser fan.
F 01 47
Faulty power electronic.
Air flap faulty.
32
KF 18xx/19xx
Remedy
See footnote (2) below
1
Replace ambient-air NTC.
Test electrical component(s) in
service mode; replace any
defective part(s).
Check the cooling circuit.
Check the wiring harness
connecting control and power
electronics; replace as
necessary.
Replace the faulty electronic.
Close the door.
Close the door.
Close the door.
Close the door.
Close the door.
Close the door.
Ensure that the machine is
properly ventilated.
Test the condenser fan in
service mode; replace if
necessary.
Replace power electronic.
Check air flap in service mode;
see Table 030-20.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kf 19 vi seriesKf 18 sf seriesKf 19 sf series