Download Print this page

Sony STR-DN1080 Manual page 60

Multi channel av receiver
Hide thumbs Also See for STR-DN1080:

Advertisement

When the measurement ends, a beep sounds and the screen switches.
Select the item you want.
3
Save: Saves the measurement results and exits the setting process.
Retry: Performs the Auto Calibration again.
Discard: Exits the setting process without saving the measurement results.
Save the measurement results.
4
Select [Save] in step 3.
If the Speaker Relocation/Phantom Surround Back screen appears, select the
5
setting you want by referring to "Calibrating speaker positioning (Speaker
Relocation/Phantom Surround Back)."
Skip to step 6 if the screen does not appear in the following cases:
The set speaker pattern does not include surround back speakers but does include
surround speakers, and [Surround Speaker Position] is set to [Front].
[In-Ceiling Speaker Mode] is set to [Front & Center] or [Front].
Select the type of calibration you want by referring to "Selecting the Auto
6
Calibration type (Calibration Type)."
When [Do you want to activate Calibration Matching?] appears on the screen, select
7
[Yes] or [No].
Yes: Expands the sweet spot for the viewing position and allows you to enjoy more
natural sound by trimming the wavefront for each pair of left/right speakers.
No: The measurement results of the Auto Calibration function are applied directly.
Select [Finish].
8
If a warning message appears
Check the warning message and select [OK]. For details on the warning messages, see "List of
messages after Auto Calibration measurements."
Hint
The measurement results may vary depending on the position of the subwoofer. However, continuing
to use the receiver with that value does not cause problems.