NEC SL1000 Features And Specifications Manual page 461

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
PRG13-04-03: 3; Transfer mode set "Remote monitor".
PRG13-04-04: 200; Set monitored terminal number.
PRG15-07-01: Set "#03" to Function key.
To start Room Monitor
1. Press Speaker+ 710 +1+monitored terminal number, "200".
- OR -
Press Function key (#03)+1+monitored dial number, "200" and Function key turn on Red (slow
flash).
2. Place incoming call from telephone which number is set at PRG13-04-01.
3. Room Monitor start at extension 200.
4. By pressing
key from outside it is possible to make both way talk.
*
To stop Room Monitor
1. Press Speaker+ 710 +0+monitored terminal number, "200".
- OR -
Press red flash Function key (#03)+0+monitored dial number, "200".
2. Place outside call from telephone which number is set at PRG13-04-01.
3. Call ring at extension 200.
Remote Inspection
< Program >
PRG11-10-49: 719 ; Auto Dial Setting for Remote
PRG20-45-01: 200; Remote Inspection terminal, 200
PRG20-45-02: 12:00; Ringing start time, 12 o'clock noon
PRG20-45-03: 3; ringing continue time, 3 minutes
PRG20-45-04: 999; Speed dial bin number, 999
PRG20-45-05: 1; VRS message number when inspected extension answered, 1
PRG20-45-06: 2; VRS message number when emergency call destination answered, 2
PRG20-45-07: 3; Times of auto repeat dial, 3
PRG20-45-08: 30; Auto dial calling time, 30 sec
PRG20-45-09: 30; Interval of Auto Dial, 30 sec
Features and Specifications Manual