NEC SL1000 Features And Specifications Manual page 33

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

ISSUE 1.0
• Up to 100 System Alarm Reports can be stored. When the buffer fills, the oldest record is deleted to
allow the new record to be saved.
• If the System is set up to E-mail the Alarm Reports and the Mail Server is down, the report is not
sent.
• System Information Reports cannot be set for output via E-mail.
• Scheduled Alarm Reports via E-mail prints all alarms. When the system detects New alarms, this in-
formation is output via E-mail individually.
• E-mail Alarm Reports can be sent when each New alarm occurs (Per Event). If you want to receive
complete Alarm Reports periodically, you must specify 12 individual dates and times in Program 90-
24-01 ~ Program 90-24-04 (per period).
A maximum of 99 entries are emailed with the scheduled alarms.
Default Settings
None
System Availability
Terminals
All Multiline Terminals
Required Component(s)
Compact Flash Card
Related Features
None
Guide to Feature Programming
Setting Up Alarms:
Program Number
90-10-01
System Alarm Setup - Alarm Type
90-10-02
System Alarm Setup - Report
90-24-01
System Alarm Report Notification Time Setup - Month
90-24-02
System Alarm Report Notification Time Setup - Day
90-24-03
System Alarm Report Notification Time Setup - Hour
90-24-04
System Alarm Report Notification Time Setup - Minute
Printing Reports:
Program Number
90-12-01
System Alarm Output - Output Port Type
Features and Specifications Manual
Program Name
Program Name
SL1000
Default
0
0
00
00
00
00
Default
0
1-25
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents