Set up Warning message
1. Press Speaker+715 at terminal.
2. Dial Security sensor number, "1".
3. Dial Internal paging group number, "01".
4. Dial external paging group number, "1".
5. Dial VRS message number for warning, "001".
6. After beep tone, record the message.
7. Press Speaker and finish recording.
Set up Auto Dial Setting for Security Sensor
1. Press Speaker+717 at Multiline terminal.
S
2. Dial Security sensor number (1-6), "1".
3. Dial Speed dial bin number to use, "999".
4. Dial emergency call destination number "xxx-xxx" and press Hold key.
5. Dial monitored terminal number, "200".
6. Dial VRS message number for destination answer, "002".
7. After beep tone, record the message.
8. Press Speaker and finish recording.
To start Security Sensor operation
1. Press Speaker+819 +1 at terminal
- OR -
2. Press Function key (
- OR -
3. Security Sensor time pattern 1 comes time to start.
To stop Security Sensor operation
1. Press Speaker+819 +0 at terminal.
- OR -
2. Press red on Function key (
- OR -
3. Security Sensor time pattern 1 comes time to stop.
When detect Security Sensor On
1. Warning message send to internal page group1 and external page group 1.
2. Place outgoing call automatically according to speed dial bin 999.
3. When destination answered send VRS message 2.
4. After finishing VRS message 2, destination person can monitor through extension 200. By press-
ing "
" key from outside it is possible to make both way talk.
*
When send Warning message
When send Warning message, but does not place emergency call case:
PRG20-46-05 is set table number, which has no setting.
When place emergency call
When place emergency call, but does not send Warning message case:
PRG20-46-02 to PRG 20-46-03 should be set to "0".
Room Monitoring from outside
< Program >
PRG11-10-45: 710 +1/0; Remote Monitor enable/disable.
PRG13-04-01: Abbreviated Dial Data; set outside telephone number which makes room monitor.
1-452
33) at multiline terminal and Function key turn on Red.
*
33) at multiline terminal and Function key turn off.
*
ISSUE 1.0