Battery Charger Fault Codes - Toro Workman GTX Electric & Lithium Service Manual

Table of Contents

Advertisement

Problem
Code E--0--2--4
Code E--0--2--5
Code E--0--3--7
Code E--0--2--9, E--0--3--0,
E--0--3--2, E--0--4--6, or E--0--6--0

Battery Charger Fault Codes

Problem
Codes F--0--0--1, F--0--0--2,
F--0--0--3, F--0--0--4, F--0--0--5,
F--0--0--6, or F--0--0--7
Workman GTX Electric Lithium
Possible Cause
Charger failed to initialize
Low AC voltage oscillation error
Re--programming failed
Communication error with battery
Possible Cause
Internal charger fault
Page 3B - - 23
Corrective Action
Disconnect the charger AC input
and battery connections for 30
seconds, then reconnect the
charger.
The charger requires an AC power
source that provides stable AC
power between 85 -- 270 VAC at
45--65 Hz. Confirm the AC power
supply capacity and verify AC input
cable gauge.
Software upgrade failure or script
operation failure. Ensure that the
new software is correct.
Ensure that the connection of the
signal wires to each battery is clean
and secure.
Corrective Action
Remove the charger AC connection
and battery connection for a
minimum of 30 seconds, then
reconnect the charger.
The battery charger may require
replacement (contact an Authorized
Toro Distributor for assistance).
Electrical System