Fault
Fault Title
Controll
ID
er(s)
Affected
B1107
Transmission
SC2
Lever Switch
Broken
U0110
CAN Bus
T
Communicatio
n Fault --
Traction Motor
1
U0111
CAN Bus
T
Communicatio
n Fault --
Battery
U1117
Source
T
Address
Contention
Fault
U1140
Communicatio
SC1
n Fault --
Battery Cell
Module
Workman GTX Electric Lithium
Fault Condition /
Additional Notes
Circuit Description
Both
Traction is disabled.
TRANMISSION_FW
D and
TRANMISSION_RE
V inputs are active
at the same time.
Primary controller
Traction is disabled.
never established
communication or
lost communication
with Traction Motor 1
controller.
Primary controller
Performance is
never established
limited.
communication or
lost communication
with battery
controller.
Controller received a
The machine is
message from
disabled.
another controller on
the CAN bus using
the same source
address.
The BMS never
Battery contactor is
established
opened.
communication or
lost communication
with at least one of
the batteries.
Page 3B - - 19
Service Actions
1) Check the switch. There
could be a short in the switch.
2) Check the
harness/connector for a loose
wire or corrosion.
1) Check CAN connection.
2) Verify power to controller.
1) Check CAN connection.
2) Verify power to controller.
Reprogram the machine
using Toro DIAG.
Check the communication
cable connection and
harness between all batteries
and the BMS.
Electrical System