NEC SL2100 Features And Specifications Manual page 83

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

ISSUE 1.0
Program
Program Name
No.
20-02-05
System Options for Multiline Telephones - Head-
set Busy Mode
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
20-13-06
Class of Service Options (Supplementary Serv-
ice) - Automatic Off-Hook Signaling (Automatic
Override)
20-13-33
Class of Service Options (Supplementary Serv-
ice) - ACD Supervisor's Position Enhancement
20-13-39
Class of Service Options (Supplementary Serv-
ice) - ACD Queue Status Display
30-05-04
DSS Console Lamp Table - ACD Agent Busy
30-05-05
DSS Console Lamp Table - Out of Schedule
(ACD DSS)
30-05-06
DSS Console Lamp Table - ACD Agent log Out
(ACD DSS)
30-05-07
DSS Console Lamp Table - ACD Agent Log In
(ACD DSS)
41-01-01
System Options for ACD - System Supervisory
Extension
41-01-02
System Options for ACD - Login ID Code Digit
41-01-03
System Options for ACD - ACD MIS Connection
Ports
41-01-04
System Options for ACD - ACD MIS Notification
when ACD Call receives Busy
41-01-05
System Options for ACD - ACD MIS Output For-
mat
41-02-01
ACD Group and Agent Assignments - ACD
Group No.
41-03-01
Incoming Ring Group Assignment for ACD
Group - ACD Group Number
41-03-02
Incoming Ring Group Assignment for ACD
Group - Night Announcement Service
41-03-03
Incoming Ring Group Assignment for ACD
Group - Priority Data
41-04-01
Group Supervisory Station Setup - Group Super-
visory Extension
41-04-02
Group Supervisory Station Setup - Operation
Type
41-05-01
ACD Agent Work Schedules
Features and Specifications Manual
Input Data
0 = No (Disable)
1 = Yes (Enable)
1 ~ 15
0 = Off (manually)
1 = On (automatically)
0 = Off
1 = On
0 = Off
1 = On
0 ~ 7 (Lamp Pattern Data)
0 ~ 7 (Lamp Pattern Data)
0 ~ 7 (Lamp Pattern Data)
1 ~ 7 (Lamp Pattern Data)
Up to eight digits (0 ~ 9,
*
, #)
0 ~ 20
0 = No Login ID
0 = Not Set
3 = LAN (CPU)
0 = Notifies
1 = No notification
0 = Classic
1 = 8-digit DDI Field
2 = Extra DDI Event
3 = XML Format
ACD Work Period Mode Number:
1 ~ 8
ACD Group Number: 0 ~ 8 (0 =
No Setting)
0 ~ 2
0 = No Setting
0 = No
1 = Yes
0, 1 ~ 7
0 = No Priority
1 = Highest Priority
7 = Lowest Priority
Up to eight digits (0 ~ 9,
, #)
*
0 = Do Not receive any ACD
Group incoming calls (No)
1 = Receive ACD Group incom-
ing calls in case of overflow
(Busy)
2 = Receive ACD Group incom-
ing calls all the time (Yes)
Work Period Mode Number = 1 ~
8
Start Time = 0000 ~ 2359
End Time = 0000 ~ 2359
SL2100
Default
0
Extension 101 is Class
15 and other Extension
are Class 1
COS 01 ~ 15 = 1
0
COS 01 ~ 15 = 0
7
0
5
4
No Setting
0
0
0
0
0
0
0
0
No Setting
0
(Start) 0000
(End) 0000
1-69
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents