Program
No.
14-02-06
Analog Trunk Data Setup - Pause after First Digit
For Manually Dialed Calls
15-02-04
Multiline Telephone Basic Data Setup - Redial
(Speed Dial) Control
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
80-03-01
DTMF Tone Receiver Setup - Detect Level
A
80-03-02
DTMF Tone Receiver Setup - Start Delay Time
80-03-03
DTMF Tone Receiver Setup - Min. Detect Level
80-03-04
DTMF Tone Receiver Setup - Max. Detect Level
80-03-05
DTMF Tone Receiver Setup - Forward Twist Level 0 ~ 9 (1 dB ~ 10 dB)
80-03-06
DTMF Tone Receiver Setup - Backward Twist
Level
80-03-07
DTMF Tone Receiver Setup - ON Detect Time
80-03-08
DTMF Tone Receiver Setup - OFF Detect Time
1-8
Program Name
Input Data
0 = No Pause (No)
1 = Pause (Yes)
0 = Common and Individual
Speed Dialing
1 = Group Speed Dialing
1 ~ 15
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
0 ~ 255 (0.25 ms ~ 64 ms)
0 ~ 15
DTMF Tone 0 = - 10 dBm (0) to -
25 dBm (15)
DTMF Tone 1 = - 15 dBm (0) to -
30 dBm (15)
DTMF Tone 2 = - 20 dBm (0) to -
35 dBm (15)
DTMF Tone 3 = - 25 dBm (0) to -
40 dBm (15)
DTMF Tone 4 = - 30 dBm (0) to -
45 dBm (15)
DTMF Tone 5 = - 35 dBm (0) to -
50 dBm (15)
DTMF Tone 6 = - 40 dBm (0) to -
55 dBm (15)
0 ~ 15
DTMF Tone 0 = 0 dBm (0) to - 15
dBm (15)
DTMF Tone 1 = - 5 dBm (0) to -
20 dBm (15)
DTMF Tone 2 = - 10 dBm (0) to -
25 dBm (15)
DTMF Tone 3 = - 15 dBm (0) to -
30 dBm (15)
DTMF Tone 4 = - 20 dBm (0) to -
35 dBm (15)
DTMF Tone 5 = - 25 dBm (0) to -
40 dBm (15)
DTMF Tone 6 = - 30 dBm (0) to -
45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
1 ~ 255 (15 + 15 ms ~ 3825 ms)
1 ~ 255 (15 + 15 ms ~ 3825 ms)
Abbreviated Dialing/Speed Dial
ISSUE 1.0
Default
1
0
Extension 101 is Class
15 and other Extension
are Class 1
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.
Refer to the Program-
ming Manual for the
default values.