Conditions
• Room Monitor is for listening only. It does not allow for conversation between the monitoring and
monitored extensions.
• An extension user cannot monitor an Attendant.
• A Multiline Terminal user cannot monitor a Single Line Terminal and a Single Line Terminal cannot
monitor a Multiline Terminals.
• Room Monitor for Single Line Terminals can be used with the Hotel/Motel feature.
• For a Multiline Terminal, Room Monitor requires uniquely programmed function keys.
• Call Arrival (CAR) Key (virtual extension) keys do not support Room Monitor Programmable
Function keys (code 39).
Default Settings
R
Disabled
System Availability
Terminals
Multiline Terminals and Single Line Terminals
Required Component(s)
None
Related Features
Hotel/Motel
Programmable Function Keys
Guide to Feature Programming
Program
No.
11-14-17
Service Code Setup (for Hotel) - Hotel Room
Monitor
15-07-01
Programmable Function Keys
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
20-13-11
Class of Service Options (Supplementary Serv-
ice) - Room Monitor, Initiating Extension
20-13-12
Class of Service Options (Supplementary Serv-
ice) - Room Monitor, Extension Being Monitored
1-736
Program Name
Input Data
0~9,
, # Maximum of 8 digit
*
-
1 ~ 15
0 = Off
1 = On
0 = Off
1 = On
ISSUE 1.0
Default
675
Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
Extension 101 is Class
15 and other Extension
are Class 1
COS 01 ~ 15 = 0
COS 01 ~ 15 = 0
Room Monitor