ISSUE 1.0
• While being monitored, an extension cannot receive Voice Over.
• When a monitored extension places a call on hold, Call Monitor is automatically finished.
• With PRG 20-13-10 set to 1, a call which is being Monitored can be placed on park by the originator
of the outside call, but only the outside caller is placed in park. The extension which is monitoring
the call is dropped.
• When PRG 20-13-10 is set to 0 (OFF), coaching is not permitted. When PRG 20-13-10 is set to 1
(ON), PRG 20-13-45 takes effect.
• When Silent Monitor Mode is used, Mute can be used to activate speech path to the internal and
external parties.
Default Settings
Disabled
System Availability
Terminals
All Terminals
Required Component(s)
None
Related Features
Barge-In
Conference
Hold
Intercom
Park
Programmable Function Keys
InMail
Guide to Feature Programming
Program
Program Name
No.
11-12-08
Service Code Setup (for Service Access) -
Barge-In
11-16-02
Single Digit Service Code Setup - Barge-In
15-07-01
Programmable Function Keys
Features and Specifications Manual
Input Data
0~9,
, # Maximum of 8 digit
*
0~9,
, # Maximum of 1 digit
*
-
SL2100
Default
710
No Setting
Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
1-135