ABB ACS560 Quick Installation And Start-Up Manual page 151

General purpose drives standard control program
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

Code
Fault / Aux. code
(hex)
aux code visible
only on assist-
ant control panel
and drive com-
poser))
1 - Maximum current limit too low
2 - Maximum speed limit or calculated
field weakening point too low
3 - Maximum torque limit too low
4 - Current measurement calibration not
finished within reasonable time
5...8 - Internal error
9 - (Asynchronous motors only). Acceler-
ation not finished within reasonable time.
A - (Asynchronous motors only) .Deceler-
ation not finished within reasonable time.
FF63
STO diagnostics
failure.
FF81
FB A force trip
FF8E
EFB force trip
Cause
SW internal malfunction.
A fault trip command
through fieldbus adapter A.
A fault trip command
through embedded fieldbus
interface.
What to do
B - (Asynchronous motors only) Speed
dropped to zero during ID run.
C - (Permanent magnet motors only). First
acceleration did not finish within reason-
able time.
D - (Permanent magnet motors only).
Second acceleration did not finish within
reasonable time.
E...10 - Internal error
11 - (Synchronous reluctance motors
only). Pulse test error.
12 - Motor too large for advanced stand-
still ID run.
13 - (Asynchronous motors only). Motor
data error.
Reboot the control unit (using paramet-
er 96.08 Control board boot or by
cycling power.
Check the fault information provided
by the PLC.
Check the fault information provided
by the PLC.
Diagnostics 151
EN
HI

Hide quick links:

Advertisement

Table of Contents
loading