Hitachi S10mini User Manual page 138

Option
Hide thumbs Also See for S10mini:
Table of Contents

Advertisement

5 USER GUIDE
[Parameters]
padr
Struct Reqmacro_p {
unsigned short *Erradr ;
unsigned long *Retdadr ;
unsigned long Para[3] ;
} ;
Be sure to specify an even-numbered address in padr.
Message transmission service
number
Remote node number
Error code storage address
CPMS macro execution result
storage address
CPMS macro parameter count
CPMS macro parameter
(*) For the relationship between real address on LPU (memory address) and symbol
name such as XW000, see "Table 2-5 Virtual Address Spare and Symbol Names."
"Memory address" in table is the address to be specified.
[Return code] (for C mode handler only)
0 (0x00000000): Normal termination
-1 (0xFFFFFFFF): Parameter abnormality exists or the handler is busy processing another
-2 (0xFFFFFFFE): When mounting S10V, specifies real address (0x01000000 to 0xFFFFFFFE)
long node ;
long ParaCnt ;
Parameter
message. Error code is stored in area which specified error code storage
address. For content and measure of error code, see "Table 7-7 List of
Detectable Codes."
on CMU at error code storage address or CPMS macro execution result
storage address. Please review the specified address.
: Input parameter storage starting address
: Remote node number (1 to 254)
: Error code storage address
: CPMS macro execution result storage address
: CPMS macro parameter count
: CPMS macro parameter
Input range
13 (only when a mathematical/logical function is
used)
1 to 254
Specify a real address (even-numbered address)
on the CPU or LPU. (*)
See [Function]
5-86

Advertisement

Table of Contents
loading

This manual is also suitable for:

S10vFl.netLqe500Lqe502

Table of Contents