5 USER GUIDE
Run request: reqrun( )
[Linking procedure]
Struct reqr_p {
long node ;
unsigned short *Erradr ;
} ;
long (*ReqRun)( ) ;
long rtn ;
struct reqr_p *padr ;
ReqRun = (long(*)( ))0xD600C0 ;/* S10V */
rtn = (*ReqRun)(padr) ;
Note: For the S10mini, substitute 0xD74130, 0xDF4130 for 0xD600C0, 0xDE00C0.
[Parameters for mathematical/logical function]
[Parameters]
padr
Struct reqr_p {
unsigned short *Erradr ;
} ;
Be sure to specify an even-numbered address in padr.
Main
+0x0000
Message transmission service number (8)
+0x0004
Remote node number (1 to 254)
+0x0008
Error code storage address
long node ;
C language
Struct reqr_p {
unsigned short *Erradr ;
} ;
long (*ReqRun)( ) ;
long rtn ;
struct reqr_p *padr ;
ReqRun = (long(*)( ))0xDE00C0 ;/* S10V */
rtn = (*ReqRun)(padr) ;
: Input parameter storage starting address
: Remote node number (1 to 254)
: Error code storage address
5-74
Sub
long node ;