Table 6-8 Pin assignments of a power adapter plate cable
Connector P1
1
3
Connection
A power adapter plate cable is connected as follows:
l
l
Ordering Information
Table 6-9
Table 6-9 Power adapter plate cable ordering information
Part Number
04151253
6.2 Wiring Terminal
6.2.1 2-Pin DC Power Terminal
Description
A 2-pin DC power cable consists of a 2-pin DC terminal block and power wires made onsite.
Make the power wires according to the power supply requirements and connect them to the
power supply system.
The 2-pin DC terminal block can prevent damages to the industrial switching router caused by
reverse connection of the power wires. Once the positive and negative wires are reversely
connected to power terminals, the industrial switching router will not be powered on.
The AR530 series and AR550 series use 2-pin DC power cables with different wire
sequences. Select the appropriate 2-pin DC power cable for the router you use.
Appearance and Structure
Figure 6-6
Issue 10 (2019-03-06)
Wire Color
Red
Black
The 4-pin connector at the P1 end is connected to the power jack on a router.
The cord end terminals (P2 and P3) are connected to a Phoenix terminal block, which is
connected to a power adapter plate.
provides the power adapter plate cable ordering information.
Description
Power Cable, 1.0m, 18AWG, H2X2(4.20),
18UL1015B+18UL1015R, T1.0^2Y
shows the structure of a 2-pin DC power terminal.
Copyright © Huawei Technologies Co., Ltd.
Cord End
Remarks
Terminal
P2
12 V
P3
GND