Huawei VS-EC-H24R User Manual page 158

Table of Contents

Advertisement

VS-EC-H24R&H28R&H29R
User Guide
Step 3
Select Trigger Channel tab and select one or more channels which will start to
record/capture or become full-screen monitoring when an external alarm is input.
Step 4
Select Arming Schedule tab to set the channel's arming schedule. Choose one day of a
week and Max. eight time periods can be set within each day.
Time periods shall not be repeated or overlapped.
Step 5
Select Handling tab to set up alarm response actions of the alarm input (please refer to
8.6 Setting Alarm Response Actions).
Repeat the above steps to set up arming schedule of other days of a week. You can also
use "Copy" to copy an arming schedule to other days, as shown in Set Arming
Schedule of Alarm Input, as shown in Figure 8-8.
Figure 8-8 Set Arming Schedule of Alarm Input
Step 6
If necessary, select PTZ Linking tab and set PTZ linkage of the alarm input.
Set PTZ linking parameters and press "OK" to complete the settings of the alarm input.
Please check whether the PTZ or speed dome supports PTZ linkage.
One alarm input can trigger presets, patrol or pattern of more than one channel. But
presets, patrols and patterns are exclusive, as shown in Figure 8-9.
Issue 04 (2013-06-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.