Configuring with Web Based Management
5.5 "System" menu
5.5.15.2

Link Change

Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
● when there should be a link on a port and this is missing.
● or when there should not be a link on a port and a link is detected.
A fault causes the signaling contact to trigger and the fault LED on the device to light up and,
depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log
table.
Description
The table has the following columns:
● Port
Shows the available ports.
● Setting
Select the setting from the drop-down list. You have the following options:
– Up
– Down
– "-" (disabled)
Procedure
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.
200
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
The error handling is not triggered.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08