Link Change - Siemens SIMATIC NET SCALANCE W780 Series Configuration Manual

Industrial wireless lan scalance w780/w740 to ieee 802.11n web based management
Hide thumbs Also See for SIMATIC NET SCALANCE W780 Series:
Table of Contents

Advertisement

Procedure
1. Click the check box in front of the line name you want to monitor to enable or disable the
monitoring function.
2. From the "PROFINET Redundancy" drop-down list, select the desired entry for redundant
power supply to be monitored by PROFINET.
3. Click the "Set Values" button.
6.5.16.2

Link Change

Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
● when there should be a link on a port and this is missing.
● or when there should not be a link on a port and a link is detected.
If a fault occurs, the error LED lights up on the device. The currently pending error is
displayed under "Information > Errors".
In addition, the corresponding error message is entered in the result log table. The content of
the event log table is displayed in "Information > Log Tables > Event Log".
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
Configuring with Web Based Management
6.5 "System" menu
253