Parsing Run Logs Offline (-O1) - Huawei IN200 User Manual

Ethernet nic
Table of Contents

Advertisement

Huawei IN200 NIC
User Guide
Format
hinicadm log -i <devicename> -t <logtype>
Parameters
Parameter
devicename
logtype
Usage Instruction
None
Example
# Query the firmware logs in the flash memory on a specified IN200.
[root@localhost tool]# hinicadm log -i hinic0 -t 1
/opt/hinic/fwlog/ up_flash_hinic0_2018_01_15_17_05_41.log create succeed.

6.1.4.3.3 Parsing Run Logs Offline (-o1)

Function
The log -o1 command is used to parse firmware and microcode run logs offline and save the
parsing results to /opt/hinic/fwlog in the tool installation directory.
Format
hinicadm log -o1 <logfile> -m <mgmt_index> -u <ucode_index>
Issue 06 (2019-07-27)
Description
Indicates the name of the
IN200 to be queried in the
system.
Indicates the type of logs to
be collected.
Copyright © Huawei Technologies Co., Ltd.
Value
Example: hinic0 and hinic1
l 0: indicates the firmware logs in the
RAM.
l 1: indicates the firmware logs in the
flash memory.
l 2: indicates the microcode logs in the
RAM.
l 3: indicates the microcode logs in the
flash memory.
l 4: indicates the last words of the
firmware and microcode.