Configuring A Management Vlan (-T Cpath_Vlan -V -S) - Huawei IN200 User Manual

Ethernet nic
Table of Contents

Advertisement

Huawei IN200 NIC
User Guide
Parameters
Parameter
devicename
Usage Instruction
None
Example
# Query the configured management VLAN.
linux-xvUVkf:~ # hinicadm sdi_cfg -i hinic0 -t cpath_vlan
None control path vlan configured.

6.1.4.42.2 Configuring a Management VLAN (-t cpath_vlan -v -s)

Function
The -t cpath_vlan-v -s command is used to configure a management VLAN.
Format
hinicadm sdi_cfg -i <devicename> -t cpath_vlan -v <vlan> -s
Parameters
Parameter
devicename
vlan
Usage Instruction
None
Example
# Configure a management VLAN.
linux-xvUVkf:~ # hinicadm sdi_cfg -i hinic0 -t cpath_vlan -v 4095 -s
Set control path vlan 4095 succeed
Issue 06 (2019-07-27)
Description
Indicates the name of the
IN200 whose FEC mode is to
be queried in the system.
Description
Indicates the name of the
IN200 whose FEC mode is to
be set in the system.
Indicates the VLAN ID.
Copyright © Huawei Technologies Co., Ltd.
6 Management Tools
Value
Example: hinic0 and
hinic1
Value
Example: hinic0 and
hinic1
It is an integer ranging
from 0 to 4095.