M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration
1.4.5 Communication Expansion Unit
1.4.5.1 CC-Link Expansion Unit
FCU8-EX561
[LED]
(1)
(2)
(3)
(4)
(5)
(6)
No.
Name
(1)
RUN
(2)
LRUN
(3)
SD
(4)
RD
(5)
ERR
(6)
LERR
Note
(1) All LED (RUN, LRUN, SD, RD, ERR, LERR) are lit during resetting of the CC-Link module.
Color
State
Green
Lit
Not lit
Green
Lit
Green
Lit
Green
Lit
Red
Lit
Flashing
Red
Lit
Flashing
Details
CC-Link module in the normal state
Watchdog timer error
Data link in process of execution
During data transmission
During data reception
Switch setting error (LERR is also lit), overlapping of mas-
ter, parameter error, communication error
Other station data link error (when it is master station.)
Data link communication error
Station and mode change during operation
27