Ethernet/Ip - Mitsubishi Electric M80 Series Maintenance Manual

Hide thumbs Also See for M80 Series:
Table of Contents

Advertisement

M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration

1.4.5.4 EtherNet/IP

FCU8-EX565
[LED]
Name
(1)
MS (Green/Red)
(Module status)
(2)
NS (Green/Red)
(Communication status) Not lit
Note
(1) Ignore LED which is not written in the table above.
IB-1501273-F
(1)
(2)
Greed LED
Red LED
Flashing
Flashing
Flashing
Not lit
Lit
Not lit
Not lit
Flashing
Not lit
Lit
Flashing green/red(alternately)
Not lit
Flashing
Not lit
Lit
Not lit
Not lit
Flashing
Not lit
Lit
(1)
(2)
Details
In self-test
Waiting for initialization
Normal operation
Recoverable failure
Unrecoverable failure (The hardware needs to be re-
placed.)
In self-diagnosis
No IP address
No connection
Normal operation
Connection time out
IP address duplication